Fire-rated assembly on the plans calls for 5/8" Type C on the ceiling but the yard only has Type X.

Prompt as given to every model

Fire-rated assembly on the plans calls for 5/8" Type C on the ceiling but the yard only has Type X. Same thickness, same rating on the label — can I sub it?

Model answers

Pick up to two to compare side by side. Score chips fill in as the judge grades.

Laguna S 2.1Score —

No — do not substitute Type X for Type C without engineering approval.

Type C and Type X are different gypsum board formulations with distinct fire-performance characteristics:

  • Type X contains fiberglass or other additives for enhanced fire resistance (typically 1-hour rated)
  • Type C is formulated with specific core additives (like vermiculite or proprietary compounds) designed for different thermal performance and may have different charring rates

While both are 5/8" and may carry similar UL labels, the chemical composition and fire-testing are not interchangeable. The fire-rated assembly was tested and listed with Type C specifically.

Code Reference:

  • IBC Section 703.4 requires fire-resistant materials to be installed per their listed assembly ratings
  • ASTM E84 and ASTM E119 testing is specific to each board type

Your Options:

  1. Get the correct Type C — this is the safest path
  2. Contact the architect/engineer for a substitution request with engineering analysis
  3. Check if the manufacturer offers a listed alternative — some brands have cross-listed assemblies

Bottom line: Even though the thickness and label rating appear identical, the core composition differs. Using Type X could compromise the assembly's actual fire rating and violate the building code. This isn't a field substitution you can approve yourself.

Get Type C or get written engineering approval before proceeding.

410 tokens · 7.5s

Judge rubric · pending

Not graded yet. Grading starts when the exam run completes.

Nemotron 3 Ultra 550BScore —

No. Type X and Type C are not interchangeable in a tested assembly, even at the same thickness and fire rating.

Why it matters

  • Type X (ASTM C1396) meets the basic 1-hr/2-hr criteria with core additives.
  • Type C (ASTM C1396, “Improved Type X”) contains additional glass fibers and vermiculite that reduce shrinkage and maintain integrity longer under fire exposure.
  • UL/ULC designs (e.g., UL Design L500 series, U300 series) list specific board types. Substituting Type X for a listed Type C voids the assembly’s fire rating.

Code references

  • IBC 2021 §703.3 – Fire-resistance ratings shall be determined by tested assemblies per ASTM E119/UL 263.
  • IBC §2508.1 – Gypsum board shall conform to ASTM C1396 and be installed per the tested assembly.
  • ASTM C1396 §5.2 – Type C is a distinct classification from Type X.

What to do

  1. Order Type C from a supplier who stocks it (often a drywall specialty yard).
  2. If the schedule is critical, submit a substitution request to the AHJ with the exact UL design number and manufacturer’s data showing equivalency — rarely approved for Type X → Type C.
  3. Document the UL design number on the submittal; the inspector will verify the board label matches the design.

Bottom line: Same thickness ≠ same performance. Install the board the assembly was tested with.