Pulling a permit for a whole-house rewire in Florida in 2026.

Prompt as given to every model

Pulling a permit for a whole-house rewire in Florida in 2026. Which edition of the NEC does the inspector enforce, and are there receptacle types I have to use?

Model answers

Pick up to two to compare side by side. Score chips fill in as the judge grades.

Laguna S 2.1Score —

NEC Edition: Florida has adopted the 2023 NEC as of March 2023 (per Florida Administrative Code R.69E-28). Unless the state amends its adoption before your 2026 permit pull, the inspector will enforce the 2023 NEC.

Receptacle Requirements (2023 NEC):

  1. Tamper-Resistant (TR) Receptacles: Required in all 15A and 20A, 125V locations (NEC 210.12). This includes bedrooms, living rooms, kitchens, bathrooms, garages, outdoors, etc.
  1. GFCI Protection: Required in kitchens, bathrooms, garages, outdoors, crawl spaces, unfinished basements, and laundry areas (NEC 210.8). Can be GFCI receptacles or GFCI breakers.
  1. AFCI Protection: Required for most 15A and 20A branch circuits supplying outlets in dwelling unit bedrooms, living rooms, family rooms, and similar areas (NEC 210.12). Typically done via AFCI breakers.
  1. Weather-Resistant (WR) Receptacles: Required for outdoor receptacles and those in damp or wet locations (NEC 406.9).
  1. GFCI+WR Combination: Outdoor GFCI receptacles must also be WR-rated (NEC 406.9(B)(3)).

Key Takeaway: Use TR-rated receptacles everywhere, GFCI-protected in wet/damp areas, AFCI-protected for bedroom/living areas, and WR-rated for outdoor/damp locations. Always verify with your local AHJ, as some jurisdictions may have additional requirements.

490 tokens · 9.0s

Judge rubric · pending

Not graded yet. Grading starts when the exam run completes.

Nemotron 3 Ultra 550BScore —

2026 Florida NEC Edition Florida operates on a 3-year adoption cycle. As of January 1, 2026, the enforceable code is the 2023 NEC (NFPA 70) with Florida-specific amendments (FBC-Energy/Building). Verify with your local building department—some jurisdictions adopt later or enforce earlier editions during transition periods.

Required Receptacle Types (2023 NEC + FL Amendments)

  1. Tamper-Resistant (TR): All 15A/20A, 125V/250V receptacles in dwelling units [210.52, 406.12]. No exceptions for height or appliance dedication.
  2. GFCI Protection: Required for all 15A/20A, 125V–250V receptacles in: Bathrooms, Garages, Outdoors, Crawlspaces, Basements, Kitchens (countertops), Sinks (within 6 ft), Laundry areas, Bathtub/shower (within 6 ft) [210.8(A)]. Note: 2023 NEC expands GFCI to all kitchen receptacles (not just countertop) and all basement receptacles (finished or not).
  3. AFCI Protection: Required for all 15A/20A, 120V branch circuits supplying outlets in dwelling unit living areas (bedrooms, living rooms, hallways, etc.) [210.12(A)]. Use Combination Type AFCI breakers or listed OBC AFCI receptacles at first outlet.
  4. Dual Function (GFCI/AFCI): Highly recommended for kitchen, laundry, and bathroom circuits to satisfy both 210.8(A) and 210.12(A) simultaneously.
  5. Weather-Resistant (WR) + TR: Required for all 15A/20A, 125V/250V receptacles in damp/wet locations (outdoors, garages, bathrooms) [406.9(A)].
  6. Surge Protection: Type 1 or Type 2 SPD required at or ahead of the service panel for all dwelling unit services [230.67].

Florida Specifics:

  • Energy Code (FBC-EC): Mandates specific receptacle placement for EV charging readiness (rough-in) in new 1- & 2-family dwellings [R404.2].
  • Hurricane Zones (HVHZ): Broward/Miami-Dade may require impact-rated boxes/covers for exterior penetrations.

Action: Buy TR/WR/GFCI/AFCI combo devices (or breakers) for 90% of the house. Confirm local amendment packet before rough-in.