New construction in Florida with the ducts in the attic.

Prompt as given to every model

New construction in Florida with the ducts in the attic. What's the duct leakage test requirement and what number do I have to hit?

Model answers

Pick up to two to compare side by side. Score chips fill in as the judge grades.

Laguna S 2.1Score —

Florida Duct Leakage Test Requirements (New Construction)

Code Reference: Florida Energy Conservation Code (FECC) 2020, based on IECC 2018, Section R403.3.

Requirements:

  • Duct leakage testing is mandatory for all new residential construction with ducts in unconditioned spaces (e.g., attics).
  • Test Method: Must comply with ACC AAH 1-2014 (or latest ACCA standard).
  • Leakage Limit:
  • ≤ 6% total leakage (measured at 25 Pa pressure) for ducts outside the conditioned space.
  • ≤ 4% total leakage if all supply and return ducts are within the conditioned space (rare in attic installs).

Key Details:

  • Test must be performed by a certified technician (BPI, RESNET, or equivalent).
  • Documentation required: Test report submitted to code official.
  • Exemptions: Ducts entirely in conditioned space (not applicable for attic ducts).

Practical Notes:

  • Use mastic or UL 181 tape for sealing joints.
  • Ensure proper access for testing (test ports).
  • Schedule inspection after testing and before drywall closure.

Bottom Line: For attic ducts in Florida new construction, you must achieve ≤ 6% leakage per ACCA standards. Test and document before final inspection.

If unsure about certification or procedures, consult a licensed HVAC or energy rater.

444 tokens · 9.8s

Judge rubric · pending

Not graded yet. Grading starts when the exam run completes.

Nemotron 3 Ultra 550BScore —

Florida (2023 FBC-Energy / 2021 IECC with FL amendments):

Test Required: Total Duct Leakage (Rough-in or Post-construction). Code Ref: R403.3.4 (mandatory), R403.3.5 (testing criteria).

The Number: ≤ 4 CFM₂₅ per 100 ft² of Conditioned Floor Area (CFA).

Critical Details for Attic Ducts:

  1. Test Method: Use a duct blaster. Pressurize to 25 Pa (0.1 in. w.c.).
  2. Rough-in Timing: Test after ducts are installed/sealed but before drywall/insulation covers connections. Register boots taped/grilles sealed. Air handler can be installed (preferred) or taped off.
  3. Post-Construction Timing: Test after finish. Register grilles installed (sealed for test). Air handler must be installed.
  4. Attic Penalty: None in FL code for total leakage limit (stays 4 CFM₂₅/100ft²). Contrast: IECC base code allows 8 CFM₂₅/100ft² for "Total" if air handler not installed at rough-in; FL Amendment R403.3.5 deletes this exception. You hit 4 CFM₂₅/100ft² regardless of stage.
  5. Ducts in Attic = R-8 Insulation Minimum (R403.3.1). Verify insulation before you bury connections.

Pro Tip: With attic ducts, target ≤ 2 CFM₂₅/100ft² at rough-in. Attic connections are hard to fix after spray foam/drywall. Seal every collar, boot-to-drywall, and AHU connection with mastic (UL 181B-M) or approved tape (UL 181B-FX). Don't rely on cloth duct tape.

Verification: Third-party certified tester (RESNET/HERS or FL licensed) required per R403.3.4. Results on Energy Code Certificate (R401.3).