Yes, multiple critical errors.
- Wrong Mortar Type (Code/Standard Violation): Type S (min. 1,800 psi) is far too hard and impermeable for 1920s soft red brick. Historic soft brick requires Type O (350 psi) or Type K (75 psi) lime-based mortar. ASTM C270 / IBC 2103.2.1 require mortar compatibility. Type S will trap moisture, spall the brick faces, and destroy the wall within freeze-thaw cycles. "Stronger is better" is false for repointing; mortar must be sacrificial.
- Grinder Damage: Angle grinders destroy soft brick arrises (edges). For historic soft brick, joints must be raked by hand (hand chisel/rake) or with an oscillating multi-tool. Grinders are prohibited on historic fabric per NPS Preservation Brief 2.
- Insufficient Depth: 1/4" is too shallow. Depth must be 2x joint width (min. 3/4"–1" for typical 3/8" joints) to ensure bond. NPS Brief 2; BIA Tech Note 7F.
- No Testing: He must perform mortar analysis (acid digestion or petrographic) to match historic sand, color, and binder ratio. Guessing causes visual and physical failure.
Stop work. Remove Type S. Source Type O/K or NHL 3.5 hydraulic lime putty mortar matched to historic sample. Rake joints by hand to proper depth. Dampen joints before pointing. Tool concave when thumbprint hard. This requires a mason experienced in historic lime mortars.