Doing a reroof in Clay County, Florida.

Prompt as given to every model

Doing a reroof in Clay County, Florida. How does the drip edge have to be installed and fastened?

Model answers

Pick up to two to compare side by side. Score chips fill in as the judge grades.

Nemotron 3 Ultra 550BScore —

Clay County, FL (FBC 8th Ed. / 2023 FBC-R) requires strict adherence to FBC-R §R905.2.8.5 and the manufacturer’s installation instructions (FBC-R §R905.1).

1. Profile & Material

  • Type: Type D (T-style) or Type F (extended flange) metal drip edge. Minimum 0.019" (26 ga) galvanized steel or 0.024" aluminum (FBC-R §R905.2.8.5).
  • Overlap: Minimum 2-inch lap at joints.

*2. Eaves (Bottom Edge) – Under Underlayment*

  • Install drip edge directly to deck before underlayment.
  • Fasteners: Ring-shank roofing nails (min 12 ga, 3/8" head) or #8 screws.
  • Spacing: Max 12" o.c. (FBC-R §R905.2.8.5). Max 4" o.c. within 4 ft of corners/edges if in High Velocity Hurricane Zone (HVHZ) or per FRSA/TRI Florida High Wind Manual (Clay County is 130–140 mph Vult; treat as high wind).
  • Seal fastener heads with asphalt plastic cement.

*3. Rakes (Gable Ends) – Over Underlayment*

  • Install over the underlayment (and ice barrier if used).
  • Same fastener type/spacing as eaves (12" o.c. field; 4" o.c. corners).
  • Extend rake drip edge over eave drip edge at corners (shed water).

4. Critical Florida Details

  • Seal the Deck: FBC-R §R905.1.1 requires a sealed roof deck (tape seams or synthetic underlayment). Run underlayment over eave drip edge flange; run rake drip edge over underlayment.
  • Kick-Out Flashing: Required at all roof-to-wall intersections (FBC-R §R903.2.1).
  • Inspection: Clay County Building Dept requires in-progress inspection (dry-in) before shingles. Leave fasteners exposed for verification.

Pro Tip: Use 1¼" ring-shank nails for 15/32" deck; 1½" for 19/32"+. Don’t staple. If deck is questionable, re-nail deck to FBC-R §R803.2.3 (6" edge/12" field) before installing drip edge.

Verify current local amendments with Clay County Building Dept (904-269-6331) before starting.

724 tokens · 7.8s

Judge rubric · pending

Not graded yet. Grading starts when the exam run completes.

Nemotron 3 Super 120BScore —

In Clay County, Florida, drip edge installation for reroofing must comply with the Florida Building Code (FBC), specifically the 2023 Florida Building Code, Residential (FBC-R), which adopts the 2021 International Residential Code (IRC) with Florida amendments.

Key Requirements for Drip Edge Installation:

  1. Placement (FBC-R R905.2.8.2 / IRC R905.2.8.2): - Drip edge must be installed at the eaves and rakes of the roof. - At eaves: Install drip edge under the underlayment, extending over the fascia and into the gutter (if present). The vertical leg should face downward. - At rakes (gable ends): Install drip edge over the underlayment, with the flange lying flat on the roof deck and the vertical leg extending down the fascia.
  1. Overlap (FBC-R R905.2.8.2): - Adjacent pieces must overlap at least 2 inches. - Ends should be lapped so water flows over the lap, not into it (i.e., upper piece overlaps lower piece).
  1. Fastening (FBC-R R905.2.8.2): - Fasten drip edge every 12 inches on center using corrosion-resistant nails (e.g., galvanized or stainless steel). - Nails must penetrate the roof deck by at least 3/4 inch or through the thickness of the deck, whichever is less. - Use nails with a minimum head diameter of 3/8 inch (e.g., roofing nails).
  1. Material (FBC-R R905.2.8): - Drip edge must be corrosion-resistant metal (minimum 26-gauge galvanized steel, 0.019-inch aluminum, or equivalent). - PVC or plastic drip edge is not permitted in Florida due to UV degradation and wind uplift concerns.
  1. Wind Uplift Compliance: - In Clay County (Wind Speed Zone: up to 150 mph, Exposure C), ensure drip edge is securely fastened to resist uplift. The FBC requires enhanced fastening in high-wind zones—follow manufacturer’s high-wind installation instructions if applicable.

Important Notes:

  • Underlayment must be installed over the drip edge at eaves and under the drip edge at rakes—this is critical for water shedding.
  • Drip edge is required on all roof replacements in Florida (FBC-R R905.2.8).
  • If unsure about local amendments, contact Clay County Building Department (904-284-6300) for confirmation—some jurisdictions may have additional requirements.

> ⚠️ If you are not a licensed roofing contractor in Florida, you may not legally perform this work. Florida Statute 489.103 requires a licensed contractor for roofing work exceeding $1,000 in value. For DIY homeowners on their own primary residence,

779 tokens · 13.1s

Judge rubric · pending

Not graded yet. Grading starts when the exam run completes.