Expect red tags on three items minimum:
- Underlayment (FBC 1507.3.3 / FRSA/TRI Manual): Clay County (HVHZ-adjacent, 130–140 mph) requires two layers of underlayment for concrete tile on slopes < 5:12. Layer 1: ASTM D226 Type II (#30) or D4869 Type IV, cap-nailed 12" o.c. Layer 2: Self-adhering polymer-modified bitumen (ASTM D1970) over the entire deck. Single-layer #30 felt fails code.*
- Tile Attachment (FBC 1507.3.7 / FRSA/TRI Appendix B, Table 1B): For 130+ mph, 4:12 hip roof, two smooth-shank nails direct-to-deck is insufficient for field tiles. You need: Ring-shank nails (min 11 ga., 5/16" head, 1.5" penetration into deck) OR screws. Perimeter/edge tiles often require two fasteners + adhesive or three fasteners. * Smooth shank lacks withdrawal resistance at design pressure.
- Hip/Ridge Installation (FBC 1507.3.8 / FRSA/TRI Ch. 7): Mortar-only is prohibited in High Velocity Hurricane Zones and 130+ mph zones. Requires mechanical attachment (stainless/coated screws or nails into a treated 2x nailer board anchored to framing) plus approved adhesive/mortar. No nailer board = no structural connection.
Other likely hits:
- Missing drip edge (FBC 1507.2.8.1).
- Missing secondary water barrier tape at deck seams (FBC 1507.3.3.2).
- Flashing details (valleys, walls) not per FRSA/TRI manual.
Fix before inspection:
- Strip felt. Install SA membrane full deck. Re-install #30 cap-nailed.
- Switch to ring-shank nails or screws per FRSA/TRI Table 1B for your tile profile/weight/zone.
- Install pressure-treated 2x nailers at hips/ridges (strapped to trusses). Fasten hip/ridge tiles mechanically + adhesive.
Do not cover until Building Official approves underlayment and nailer installation.