Setting a treated sill plate on a new stem wall.

Prompt as given to every model

Setting a treated sill plate on a new stem wall. What size anchor bolts, how far apart, and how deep do they have to be?

Model answers

Pick up to two to compare side by side. Score chips fill in as the judge grades.

Laguna S 2.1Score —

Anchor Bolt Size & Spacing: Use ½-inch diameter galvanized anchor bolts, minimum 12 inches long. Space them 4 feet on center maximum, with one within 12 inches of each corner and wall end (IRC R602.11.1).

Embedment Depth: Minimum 7 inches into concrete (IRC R602.11.1). For 4-inch-thick stem walls, use ½" x 10" bolts to achieve adequate embedment while allowing for sill plate thickness and nut clearance.

Installation Tips:

  • Drill ⅝-inch diameter holes in concrete for ½-inch bolts (allow clearance for alignment).
  • Place bolts after concrete has cured (typically 7 days for full strength).
  • Use anchor straps or holdowns at shear walls and braced wall lines per IRC R602.10.
  • Ensure bolts are plumb and properly aligned before concrete sets.

Code Reference: IRC R602.11 (Sill Plate Anchoring) requires anchoring to resist both uplift and lateral forces. Local seismic or wind zones may require closer spacing or additional anchors.

Safety Note: If your area has high wind or seismic loads, consult a structural engineer for specific requirements. Always wear eye protection when drilling into concrete.

370 tokens · 6.7s

Judge rubric · pending

Not graded yet. Grading starts when the exam run completes.

Nemotron 3 Ultra 550BScore —

IRC R403.1.6 / IBC 1901.3 (ACI 318)

Bolt Size: ½-inch diameter minimum (ASTM F1554 Grade 36 or A307). ⅝-inch is common for heavier loads/high wind/seismic.

Spacing: Maximum 6 feet on center (o.c.).

  • Critical: Within 12 inches of every plate end, splice, and corner (IRC R403.1.6.1).
  • Seismic D₀, D₁, D₂ / High Wind: Reduce to 4 ft o.c. (check local amendment).

Embedment Depth: 7 inches minimum into concrete/grout (IRC Table R403.1.6).

  • Pro Tip: Order bolts 10–12 inches long. This gives you 7" embed + 3–4" for 2x sill (1.5"), washer/nut (1"), and adjustment room for uneven stem wall tops.

Washers: Plate washers required (3"x3"x0.229" min / ¼" thick) per IRC R403.1.6. Standard cut washers are not code-compliant for sill plates.

Layout Tips:

  1. Snap chalk lines for plate location before pouring.
  2. Use a bolt template (2x4 with holes drilled 6' o.c. + 12" from ends) to hold bolts plumb during pour.
  3. Protect threads with tape/nuts while pouring.
  4. Treated Sill: Use hot-dip galvanized (HDG) or stainless steel bolts/nuts/washers (IRC R317.3). Standard zinc-plated will corrode.

If: Stem wall is CMU (block), embed J-bolts 15 inches into grouted cells (IRC R403.1.6.2) or use epoxy-set anchors (ICC-ES report required) post-pour.

Verify local amendments—some jurisdictions require ⅝" bolts or 4' spacing universally.