Roughing in a toilet in a small half bath.

Prompt as given to every model

Roughing in a toilet in a small half bath. What clearances do I have to hold?

Model answers

Pick up to two to compare side by side. Score chips fill in as the judge grades.

Nemotron 3 Ultra 550BScore —

Per IPC 405.3.1 / UPC 407.2 (check local amendments):

Minimums (to center of flange):

  • Sidewalls: 15" min each side (30" total width).
  • Front obstruction (wall/vanity): 21" min (IPC) / 24" min (UPC) from front of bowl.
  • Back wall (rough-in): Standard 12" (10" or 14" exist—verify bowl spec).

Small Bath Strategy:

  1. Use a 10" rough-in toilet if tight to back wall. Saves 2" vs standard.
  2. Wall-hung toilet (carrier in wall): Maximizes floor clearance for cleaning/doors; requires 2x6 wall or chase.
  3. Corner toilet: Only if flange centers hit 15" off both walls.
  4. Door swing: Ensure door doesn't hit bowl (IPC 405.3.2). Pocket/out-swing door saves 24"+.

Code Trap: The 15" side clearance is to the flange center, not the tank. Tank can overhang baseboard, but flange must hold 15".

Pro Tip: Snap chalk lines for 15"/15" and 12" (or 10") before drilling subfloor. Verify with actual bowl template—elongated bowls need the full 21"/24" front clearance; round bowls save ~2".

If <30" wide or <21" front clearance: You need a variance or a different fixture (e.g., composting/incinerating toilet if code allows). Don't guess—call the inspector.

468 tokens · 48.8s

Judge rubric · pending

Not graded yet. Grading starts when the exam run completes.

Nemotron 3 Super 120BScore —

For a toilet rough-in in a half bath, the key clearances are governed by the International Residential Code (IRC), specifically Section P2705.1 (Toilet Compartment Size) and Section R307.1 (Minimum Fixture Clearances). Here are the practical, code-compliant minimums:

Minimum Clearances (IRC 2021/2024):

  • Centerline to sidewall (or obstruction): Minimum 15 inches from the toilet’s centerline to the nearest wall, vanity, or fixture. (This ensures 30" total width for the fixture — 15" each side of centerline.)
  • Front clearance (to opposite wall or fixture): Minimum 21 inches from the front of the toilet bowl to the nearest obstruction (e.g., wall, vanity, door). (Note: Some jurisdictions or accessibility guidelines (ADA) require 30" front clearance — but for standard residential half baths, 21" is the IRC minimum.)
  • Side clearance to adjacent fixture (e.g., sink): Minimum 15 inches from toilet centerline to the edge of a sink or vanity. (If the sink is offset, measure from toilet centerline to sink’s closest edge.)
  • Clearance from toilet to bathtub/shower: Minimum 18 inches centerline-to-centerline (IRC P2705.1.2), though 24" is recommended for comfort.

Practical Tips for Small Half Baths:

  • Verify local amendments: Some municipalities adopt stricter rules (e.g., 24" front clearance). Always check with your local building department.
  • Door swing: Ensure the door doesn’t swing into the required 21" front clearance. If it does, consider a pocket door or outward-swinging door.
  • Flange placement: Set the toilet flange 12" from the finished wall (standard rough-in). This centers the toilet bowl properly — critical for meeting the 15" sidewall rule.
  • Avoid crowding: In tight spaces, prioritize front clearance (21") over side clearance if forced to choose — users need room to sit and stand.

> ⚠️ If the space is under 30" wide or 60" deep, you may not meet code for a functional toilet compartment. Consider consulting a licensed plumber or designer — especially if modifying walls or plumbing. > Never sacrifice clearance for convenience — non-compliant rough-ins fail inspection and create usability/safety issues.

For most half baths, aim for 30" wide x 60" deep as a comfortable, code-safe footprint. If smaller, document your reasoning and seek a variance — but 21" front + 15" side is the absolute IRC floor.