Exam questions
Public bank tasks, grouped by family · the full v1.0 bank is public
Knowledge 20
Practical how-to a journeyman knows cold.
- Task PL-001
I'm running a 3-inch main drain and a 2-inch branch under a slab. What slope do I need on each?
Knowledge - Task PL-002
How deep is the water seal in a P-trap supposed to be, and why does it matter if it's deeper?
Knowledge - Task PL-003
How far can I run a 1-1/2 inch lavatory trap arm before it has to hit a vent? What about a 2-inch trap arm for a kitchen sink?
Knowledge - Task PL-004
Give me the rules for the T&P relief valve discharge pipe on a tank water heater.
Knowledge - Task PL-005
I'm setting a 50-gallon electric heater in a second-floor laundry closet. What are the requirements for the drain pan?
Knowledge - Task PL-006
House has 95 psi static at the hose bib. Do I need a pressure reducing valve, and what else changes once I put one in?
Knowledge - Task PL-007
Repiping from old galvanized to copper in a 1960s house. How am I supposed to make the transition where copper meets the remaining galvanized?
Knowledge - Task PL-008
Walk me through solvent-welding a 3-inch PVC DWV joint the right way.
Knowledge - Task PL-009
Which fittings can I use for a horizontal-to-horizontal change of direction on a drain line, and where is a sanitary tee actually allowed?
Knowledge - Task PL-010
How tall does a washing machine standpipe need to be and what size trap?
Knowledge - Task PL-011
Hanger spacing: how often do I have to support horizontal PVC DWV, 1/2 inch copper, 3/4 inch PEX, and cast iron?
Knowledge - Task PL-012
What kind of valve is required on a tub/shower, and what temperature is it supposed to be set to?
Knowledge - Task PL-013
Roughing in a toilet in a small half bath. What clearances do I have to hold?
Knowledge - Task PL-014
Single-family house: two full baths (1.6 gpf toilets, lav, tub), a kitchen sink with disposer and dishwasher, and a washer. Can the building drain be 3 inch at 1/8 in/ft? Show the DFU math.
Knowledge - Task PL-015
Building a tile shower on a mud bed with a PVC pan liner. What are the liner rules and how is the liner tested?
Knowledge - Task PL-016
What's the right way to sweat a 3/4 copper joint so it doesn't leak, and what's the trick when there's still water in the line?
Knowledge - Task PL-017
Homeowner says the T&P valve on the water heater drips every evening and they've already replaced it twice. Pressure at the hose bib is 65 psi. What's going on and what do I do?
Knowledge - Task PL-018
Do outside hose bibs need any kind of backflow protection?
Knowledge - Task PL-019
When can I use an air admittance valve (Studor vent) instead of running a vent through the roof, and what are the installation rules?
Knowledge - Task PL-020
Where am I required to put cleanouts on a residential building drain and sewer, and how big?
Knowledge
Code 8
Code and spec lookups with the jurisdiction stated.
- Task PL-021
I'm replacing a sewer line in a front yard in Clay County, Florida. Do I have to call anything before I dig, and how far ahead?
Code - Task PL-022
How deep does a building sewer and the water service have to be buried in Florida?
Code - Task PL-023
Where can I terminate a plumbing vent through the roof, and how close can it be to a bedroom window?
Code - Task PL-024
What test does the inspector want on a new water supply rough-in, and can I use air?
Code - Task PL-025
DWV rough inspection on a two-story house in Jacksonville. What head of water does the inspector expect on the water test, and is it the same as the model IPC?
Code - Task PL-026
Installing a gas tank water heater in an attached garage. What does code say about height and the pan?
Code - Task PL-027
Customer wants me to tee a new irrigation system off the house service. What backflow device is required and do I need to get it tested?
Code - Task PL-028
Master bath is on the far end of the house from the water heater, about 70 feet of pipe. Is there a code limit on how far hot water can run?
Code
Catch 12
Bad premise or hidden hazard. A good answer catches it.
- Task PL-029
Apprentice roughed in a bathroom lav: 1-1/2 inch P-trap, trap arm runs 9 feet horizontally at 1/4 per foot to a sanitary tee on the 2-inch vent/stack. He says it's fine because it's 'sloped right and vented.' What's the problem?
Catch - Task PL-030
Under a slab, a helper joined a 3-inch horizontal branch into the 4-inch horizontal building drain with a 4x3 sanitary tee laid on its back, because 'that's what fit.' Inspection is tomorrow. What's wrong?
Catch - Task PL-031
Handyman replaced a 40-gallon gas heater in a closet. To reach the floor drain he ran the T&P discharge up over a shelf and down in 1/2 inch PEX with a threaded adapter on the end, and tied it into the drain with a glued fitting. Heater works. What did he get wrong?
Catch - Task PL-032
On a new 50-gallon gas atmospheric heater, the plumber crimped 3/4 PEX directly onto the heater's top nipples with brass PEX adapters and ran it straight to the manifold. Owner wants to know if that's OK.
Catch - Task PL-033
Tile guy built a mud-set shower: laid the PVC liner flat on the plywood, packed the mud bed on top, screwed the liner to the curb 1/2 inch above the curb top, and slathered thinset around the drain base to 'seal it.' It flood tested fine. Why will this shower fail?
Catch - Task PL-034
Slab-on-grade addition in Florida. The plumber ran the 3/4 copper water lines through the slab pour with no sleeve, poured monolithic, then stubbed up in the wall. What's coming?
Catch - Task PL-035
Remodel: kitchen island sink vented with an AAV under the cabinet, bathroom group vented with an AAV in the attic sitting on the branch under the blown insulation, and the old roof vent was capped because 'we don't need it now.' Inspector's coming. What fails?
Catch - Task PL-036
Cold morning, 42 degrees. Helper glued twelve 4-inch PVC sewer joints with cement only (no primer, 'it's the all-in-one kind'), didn't twist them, and 10 minutes later put 30 psi of air on the line to test it. Where's this going?
Catch - Task PL-037
Sewer replacement: 60 feet of 4-inch PVC from the house to the tap at the street, laid at 1/16 per foot because the tap was shallow, joined to the old cast iron stub with an unshielded Fernco rubber coupling, no cleanout at the house, and backfilled with the excavated limerock and chunks of old concrete. Inspector already passed it on a drive-by. What's wrong and what happens later?
Catch - Task PL-038
Bath remodel: contractor set the closet flange 1 inch below the new tile floor and stacked two wax rings to make up the gap, and the flange centerline sits 13 inches from the new vanity. He says toilets get set like this all the time. What's wrong?
Catch - Task PL-039
Restaurant build-out: the plumber hard-piped the 3-compartment sink with a P-trap straight into the branch feeding the grease interceptor, ran the ice machine drain and the prep sink directly into the sanitary line with traps, and set the walk-in cooler floor drain with a trap inside the box. Health and plumbing inspection is Friday. What gets flagged?
Catch - Task PL-040
Laundry room: the plumber cut the washer standpipe off at 12 inches above the trap to fit under the counter, used a 1-1/2 inch P-trap, and pushed the washer hose into the pipe with a rubber grommet so 'it wouldn't splash.' Washer supply valves are plain quarter-turn ball valves with no arrestors. Problems?
Catch